WaveControl Field Probe Selection

WaveControl Field Probe Selection Graph

SMP3 Versions

WP10M Field Probe

  • 1 Hz – 10 MHz
  • E & H field
  • Selective & Broadband
  • Energy: IEC/EN 62110
  • Railway: EN 50500
  • Welding: EN 50505
  • Induction heating (LF): EN 50519
  • Electric arc or induction smelting
  • Household appliances: IEC/EN 62233, EN 50366
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Medical: IEC 60601
  • Research/Labs
  • Electronic/electrical equipment: IEC/EN 62311
  • Defense (LF) 
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Automotive
WaveControl WP10M

Compatible with:

SMP3
SMP3
WaveControl WP50

Compatible with:

SMP3
SMP3
SMP2
MonitEM

WP50 Field Probe

  • 10 Hz – 3 kHz
  • E & H field
  • Broadband
  • Energy: IEC/EN 62110
  • Induction heating: EN 50519
  • Electric arc or induction smelting
  • Workplace assessment: EN 50499
  • Human exposure assessment: EN 50413
  • Other low frequency applications
  •  

WP400 Field Probe

  • 1 Hz – 400 kHz
  • E & H field
  • Selective & Broadband
  • Energy: IEC/EN 62110
  • Railway: EN 50500
  • Welding: EN 50505
  • Induction heating (LF): EN 50519
  • Electric arc or induction smelting
  • Household appliances: IEC/EN 62233, EN 50366
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Medical: IEC 60601
  • Research/Labs
  • Electronic/electrical equipment: IEC/EN 62311
  • Defense (LF) 
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Automotive
    •  
WaveControl WP400

Compatible with:

SMP3
SMP3
SMP2
WaveControl WP400

Compatible with:

SMP3
SMP3
SMP2

WP400c Field Probe

  • 1 Hz – 400 kHz
  • E & H field
  • Selective & Broadband
  • Automotive
  • Energy: IEC/EN 62110
  • Railway: EN 50500
  • Welding: EN 50505
  • Induction heating (LF): EN 50519
  • Electric arc or induction smelting
  • Household appliances: IEC/EN 62233, EN 50366
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Medical: IEC 60601
  • Research/Labs
  • Electronic/electrical equipment: IEC/EN 62311
  • Defense (LF) 
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
      •  

WP400-3 Field Probe

  • 1 Hz – 400 kHz
  • E & H field
  • Selective & Broadband
  • Assessment of:
      • Welding equipment: IEC/EN 62822, EN 50505
      • Household appliances: IEC/EN 62233, EN 50366
      • Other electronic/electrical equipment: IEC/EN 62311
    • Research/Labs 
    • Other application where small size and spatial resolution is important
    •  
  •  
WaveControl WP400-3

Compatible with:

SMP3
SMP3
SMP2

Compatible with:

SMP3
SMP3
SMP2
MonitEM
MonitEM-Lab

WPF3 Field Probe

  • 100 kHz – 3 GHz
  • E field
  • Broadband
  • Telecommunications:
    • Wireless telecom networks: IEC 62232, EN 50400, EN 50401
    • Broadcast: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Induction heating (HF): EN 50519
  • Plastic welding
  • Semiconductor production
  • Medical: IEC 60601
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Microwave drying

WPF6 Field Probe

  • 100 kHz – 6 GHz
  • E field
  • Broadband
  • Telecommunications:
    • Wireless telecom networks: IEC 62232, EN 50400, EN 50401, EN 50492
    • Broadcast: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Induction heating (HF): EN 50519
  • Plastic welding
  • Semiconductor production
  • Medical: IEC 60601
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Microwave drying

Compatible with:

SMP3
SMP3
SMP2
MonitEM
MonitEM-Lab
WPF8

Compatible with:

SMP3
SMP3
SMP2
MonitEM
MonitEM-Lab

WPF8 Field Probe

  • 100 kHz – 8 GHz
  • E field
  • Broadband
  • Telecommunications:
    • Wireless telecom networks: IEC 62232, EN 50400, EN 50401, EN 50492
    • Broadcast: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Induction heating (HF): EN 50519
  • Plastic welding
  • Semiconductor production
  • Medical: IEC 60601
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Microwave drying

WPF18 Field Probe

  • 300 kHz – 18 GHz
  • E field
  • Broadband
  • Telecommunications:
    • Wireless telecom networks: IEC 62232, EN 50400, EN 50401
    • Broadcast: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Induction heating (HF): EN 50519
  • Plastic welding
  • Medical: IEC 60601
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Microwave drying
  • Radar
  • Defense (HF)
  •  

Compatible with:

SMP3
SMP3
SMP2
MonitEM
MonitEM-Lab

Compatible with:

SMP3
SMP3
SMP2
MonitEM
MonitEM-Lab

WPF40 Field Probe

  • 1MHz – 40 GHz
  • E field
  • Broadband
  • Telecommunications:
    • Wireless telecom networks: IEC 62232, EN 50400, EN 50401
    • Broadcast: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Induction heating (HF): EN 50519
  • Plastic welding
  • Medical: IEC 60601
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Microwave drying
  • Radar
  • Defense (HF)

WPF60 Field Probe

  • 1MHz – 60 GHz
  • E field
  • Broadband
  • Telecommunications:
    • Wireless telecom networks: IEC 62232, EN 50400, EN 50401
    • Broadcast: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
    • Satellite installations
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Microwave drying
  • Detection of leaks
  • Radar
  • Defense (HF)
WPF60

Compatible with:

SMP3
SMP3
SMP2
MonitEM
MonitEM-Lab
WPF60S

Compatible with:

SMP3
SMP3
SMP2

WPF60S Field Probe

  • 1 MHz – 60 GHz
  • Shaped (FCC / ICNIRP)
  • E field – Broadband
  • Telecommunications:
    • Wireless telecom networks: IEC 62232, EN 50400, EN 50401
    • Broadcast: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
    • Satellite installations
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Microwave drying
  • Detection of leaks
  • Radar
  • Defense (HF)

WPH60 Field Probe

  • 300 kHz – 60 MHz
  • H field
  • Broadband
  • Broadcasting: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Induction heating (HF): EN 50519
  • Medical: IEC 60601
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs

Compatible with:

SMP3
SMP3
SMP2
MonitEM

Compatible with:

SMP3
SMP3
SMP2
MonitEM
MonitEM-Lab

WPH1000 Field Probe

  • 30 MHz – 1000 MHz
  • H field
  • Broadband
  • Broadcasting: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Induction heating (HF): EN 50519
  • Medical: IEC 60601
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Defence

WPH-DC Probe

  • DC – 40 kHz
  • H Field
  • Selective & Broadband
  • Medical (MRI: Magnetic Resonance Imaging): IEC 60601-2-33
  • Railway (DC Motors): EN 50500
  • Automotive (Electrical vehicles)
  • Chemical Industry (Electrolysis)
  • Strong Permanent Magnets (Heavy duty magnet lifters)
  • Energy (DC generators)
  • Metrology (Earth static field)

Compatible with:

SMP3
SMP3
SMP2
WPT

Compatible with:

SMP3
SMP3
SMP2
MonitEM

WPT Field Probe

  • Bands: 700-900, 1800-1900, 2100 and 2600
  • E field
  • Selective broadband
  • Assessment of mobile telephony base stations

WP-WiFi Field Probe

  • Band: 2400-2500
  • E field
  • Selective broadband
  • Assessment of WiFi transmitters
WPTWIFI

Compatible with:

SMP3
SMP3
SMP2
MonitEM

Ready to get started?

Contact us for a free quote today.

Request Quote

    Request a Quotation