Hioki SW1001 Switch Mainframe

Hioki SW1001 Switch Mainframe

The SW1001 is a switch mainframe for housing up to 12 units of SW9001 or SW9002 Multiplexer Module to deliver quick, multi-channel battery testing. Connect up to 2 battery testing instruments to test OCV measurement, internal resistance measurement, and external potential measurement of battery cells.

Basic specifications

Slots 3 slots
Supported modules MULTIPLEXER MODULE SW9001 (2-wire/4-wire)
MULTIPLEXER MODULE SW9002 (4-terminal pair)
Connectible instruments Max. 2 units
2-wire × 1 + 4-wire × 1, or 2-wire × 1 + 4-terminal pair × 1
Max. input voltage 60 V DC (Cannot connect to battery packs in excess of 60 V DC), 30 V AC rms, 42.4 V peak, Maximum rated voltage to ground: 60 V DC
Communication I/F LAN, USB, RS-232C (for host, for measurement instruments)
Functions Channel switching, wiring method, scan function, communication command transmission, channel delay, shield switching
Power supply 100 to 240 V AC / 30 VA (50/60 Hz)
Dimensions and mass 215 mm (8.46 in) W × 132 mm (5.20 in) H × 420 mm (16.54 in) D, 3.7 kg (130.5 oz)
Accessories Power cord ×1, instruction manual ×1, usage precautions ×1, USB driver CD ×1

Basic specifications for MULTIPLEXER MODULE

SW9001 SW9002
Wiring method 2-wire or 4-wire 4-terminal pair (6-wire) or 2-wire
No. of channels 22 channels (2-wire) / 11 channels (4-wire) 6 channels (4-terminal pair) / 6 channels (2-wire)
Contact method Armature relays
Channel switching time 11 ms (excluding measurement time)
Max. allowable voltage 60 V DC, 30 V AC rms, 42.4 V peak
Max. allowable current 1 A DC, 1 A AC rms 1 A DC, 1 A AC rms (Sense), 2 A DC, 2 A AC rms (Source, Return)
Max. allowable power 30 W (resistive load)
Maximum rated voltage to ground 60 V DC
Dimensions and mass 25.5 mm (1.00 in) W × 110 mm (4.33 in) H × 257 mm (10.12 in) D, 210 g (7.4 oz) 25.5 mm (1.00 in) W × 110 mm (4.33 in) H × 257 mm (10.12 in) D, 196 g (6.9 oz)
Accessories Instruction manual ×1

 

Category:

You may also like…

Key Features

  • Switch between voltmeter and battery tester while testing
  • SW1001: max. 66 channels (2-wire) to max. 18 channels (4-terminal pair)
  • Circuit-design-friendly for impedance measurements that minimize errors between channels (Effect: 0.01% f.s.*)
  • For BT4560 100 mΩ range, R measurements, and a measurement frequency of 1 kHz
  • For OCV measurement, internal resistance measurement, and external potential measurement of battery cells
  • Measure battery modules up to 60 V DC

 

Application Notes