Raditeq RadiSense® RSS2010E (Set)

Raditeq RadiSense® RSS2010E (Set)

RadiSense 10E LASER powered E-field probe set

Specifications

  • Frequency range: 20 MHz to 10 GHz
  • Measuring range: 0.5 V/m to 200 V/m
  • Frequency response: 20MHz to 1GHz -3dB/+1.5dB, 1GHz to 10GHz -3dB/+3.5dB
  • Isotropy: < +/- 0.5 dB up to 1 GHz, typically 0.25dB
  • Measuring speed: 15 measurements/second

Standard delivery including

  • RSS2010E E-field probe
  • LPS2001B LASER power plug-in card (for RadiCentre®)
  • CBL2001-10M Optic fibre extension cable (10 meters)
  • CPL2001A Optic fibre coupling connectors FC/ST (2x)
  • PST2000A Probe stand – including 4 height rods
  • CTR1001S RadiCentre® slim – modular test system
  • RSS2010 CASE RadiSense® carrying and protective case

Upgrade options

  • ISO17025 accredited calibration
  • PST1001A – 2.3 Meter non-refelective Probe stand used for 16-point calibrations

Category:

Key Features

What is the RadiSense® Essential?
The RadiSense® Essential probe makes the highly accurate RadiSense probes accessible for every budget. The probe is based on proven design of the RSS2010H probe (Pro series). During the development of the RSS2010E, no compromises were made to the measurement accuracy of this new model. On top of this, the RSS2010E still offers the convenience of a laser powered probe, for the price of a battery powered probe! Although this model has reduced measurement range and speed specifications compared to the Pro series probes, It is still faster compared to battery powered probes available on the market!

Superb Isotropy
During tests in an anechoic chamber, the surrounding walls, floor and ceiling will cause reflections. These reflections arrive at the probe elements from different angles. This results in large and unpredictable measurement errors when your probe is not isotropic. Like all other RadiSense® probes, the RSS2010E has an excellent isotropic behavior. In contradiction to most other probes, the isotropic response of the RSS2010E is specified over its full frequency range!

Internal calibration data
Like the RadiSense® Pro series probes, the linearity correction data is stored inside the probe. Additionally, the frequency response calibration data for the individual X-Y-Z axis, can be stored inside the probe by the user. As a result, there is no need to apply frequency dependent correction factors for each individual axis in the PC software. This feature results in higher accuracy, faster measurements and ease-of-use.

Laser Powered
Despite its attractive price, the RSS2010E probe still is a Laser powered probe! This means that nobody has to deal with the limitations of battery powered E-field probes anymore. Perform E-field measurements at high accuracy and without interruptions!

Application Notes