EMSense for Battery-Powered E-Field Probes Model 7007-001
ETS-LINDGREN’S EMSense MODULAR PLUG-IN CARD provides an interface for ETS-Lindgren’s battery-powered E-field probes.
Each EMSense modular plug-in card supports one ETS-Lindgren E-field probe. EMSense and ETS-Lindgren probes are fully supported by TILETM and other test automation software packages.
EMSense is fully compatible with all ETS-Lindgren E-field battery-powered probes, covering a frequency range of 10 kHz – 40 GHz and a dynamic range of 0.5 – 800 V/m and occupies one slot in the EMCenter platform, allowing additional slots to be occupied by modular plug-in cards for positioning controllers, multiple RF switches and more.
Performance Specifications (E-Field Probes)
MODEL FEATURE |
HI-6022 |
HI-6005 |
HI-6053 |
Detection Isotropic |
Isotropic (X, Y and Z Axis Readings) |
Isotropic (X, Y and Z Axis Readings) |
Isotropic (X, Y and Z Axis Readings) |
Calibrated Frequency Range |
10 kHz to 1 GHz |
100 kHz to 6 GHz |
10 MHz to 40 GHz |
Frequency Response (Typical) |
10 kHz to 30 kHz +0.5, – 2.5 dB |
500 kHz to 2 GHz +1.0, -2.5 dB |
10 to 100 MHz + 3.0, -4.0 dB |
Frequency Response with Correction |
± 0.9 dB |
± 0.9 dB |
10 MHz to 18 GHz ± 0.9 dB |
Dynamic Range |
2.0 to 800 V/m (Single Range) |
0.5 – 800 V/m (Single Range) |
2.0 to 800 V/m (Single Range) |
Resolution |
0.01 V/m |
0.01 V/m |
0.01 V/m |
Isotropic Deviation |
± 0.5 dB @ 400 MHz |
± 0.5 dB @ 400 MHz |
±1.0 dB < 18 GHz |
Linearity |
± 0.5 dB @ 27 MHz |
± 0.5 dB @ 27 MHz |
±0.5 dB @ 1 GHz |
Sample Rate |
60 Samples/Second Maximum |
60 Samples/Second Maximum |
60 Samples/Second Maximum |
Overload Withstand |
>1500 V/m CW |
>1500 V/m CW |
>1500 V/m CW |