Hioki DT4282 DIGITAL MULTIMETER

Hioki DT4282 DIGITAL MULTIMETER

£455.84 exc. VAT

Out of stock

Introducing the world-renowned DIGITAL MULTIMETER DT4282, the premier digital multimeter for laboratory and R&D applications. With superior accuracy and high response, this powerful device offers a wide range of measuring capabilities, including DC and AC current, conductance, and more.

The DT4282 features a low-pass filter function that eliminates harmonic components, allowing for accurate measurement of fundamental waves. It also offers peak value measurement and DC + AC voltage measurement for ripple voltage measurement in DC charging systems.

This digital multimeter also has a percentage display for 4 to 20 mA instrumentation signals, allowing for the conversion and display of instrumentation signals from transducers or other devices.

Designed and manufactured in Japan, the DT4282 is made with the highest quality materials and is backed by a 3-year warranty for peace of mind. Safety is paramount, and the DT4282 includes safety terminal shutters and optical communications to ensure electrical hazards are minimized.

With its advanced technological capabilities and unmatched precision, the DIGITAL MULTIMETER DT4282 is the ultimate tool for accurate and reliable measurements in any laboratory or R&D setting.

  • Hioki DT4221: This model is a compact digital multimeter with a variety of measurement capabilities, including voltage, current, resistance, frequency, and temperature.
  • Hioki DT4222: This model is similar to the DT4221 but without the capacitance measurement capability.
  • Hioki DT4223: This model is similar to the DT4222 but with the capacitance and temperature measurement capabilities.
  • Hioki DT4252: This model is designed for measuring low-level currents, with a range of 2mA to 20mA.
  • Hioki DT4253: This model is similar to the DT4252 but with a higher current measurement range of 2mA to 200mA.
  • Hioki DT4255: This model is designed for measuring high voltages and currents, up to 600V and 10A, respectively.
  • Hioki DT4256: This model is similar to the DT4255 but with slightly higher voltage and current measurement capabilities (up to 1000V and 20A, respectively).
  • Hioki DT4261: This model has a high resolution and accuracy and is designed for use in industrial settings.
  • Hioki DT4281: This model is designed for high-speed measurement and can measure up to 120,000 times per second.
  • Hioki DT4282: This model is similar to the DT4281 but also includes a built-in data logger for recording measurements over time.

Basic specifications (Accuracy guaranteed for 3 years, Post-adjustment accuracy guaranteed for 3 years)

DC Voltage range 60.0 mV to 1000.0 V, 6 ranges, Basic accuracy: ±0.025 % rdg. ±2 dgt.
AC Voltage range* 60.00 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz – 100 kHz
Basic accuracy 40 – 65 Hz : ±0.2 % rdg. ±25 dgt. (True RMS, crest factor 3)
AC + DC Voltage range* 60.00 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz – 100 kHz
Basic accuracy 40 – 65 Hz : ±0.3 % rdg. ±25 dgt. (True RMS, crest factor 3)
Resistance range 60.000 Ω to 600.0 MΩ, 8 ranges, Basic accuracy: ±0.03 % rdg ±2 dgt
DC Current range 600.00 μA to 10.000 A, 6 ranges. Basic accuracy: ±0.05 % rdg ±5 dgt
AC Current* range 600.00 μA to 10.000 A, 6 ranges. Basic accuracy 45 – 65 Hz : ±0.6 % rdg ±5 dgt (True RMS, crest factor 3).
Peak DC DC V measurement: Signal width 4 msec or more (single), 1 msec or more (repeated).
Peak AC AC V, DC/AC A measurement: Signal width 1 msec or more (single), 250 μsec or more (repeated)
Capacitance range 1.000 nF to 100.0 mF, 9 ranges, Basic accuracy: ±1.0 % rdg ±5 dgt
Frequency range AC V, DC+AC V, AC A measurement,99.999 Hz  to 500.00 kHz, 5 ranges, ±0.005 % rdg ±3 dgt
Continuity check Continuity threshold: 20/50/100/500 Ω, Response time: 10 ms or more
Diode test Open terminal voltage: 4.5 V or less, Testing current 1.2 mA or less, Threshold of forward voltage: 0.15 V to 3 V, seven stages
dB conversion Standard impedance setting (dBm), 4 Ω to 1200 Ω, 20 stages Display dB conversion value of AC voltage (dBV)
Temperature
(thermocouples)
K: -40.0 °C to 800.0 °C (-40.0 °F to 1472.0 °F)
Add accuracy of the Thermocouple probe to main unit accuracy: ±0.5 % rdg ±3 °C
Other functions Filter function, Display value hold, Auto hold, Max/Min value display, Sampling select, Relative display, Measurement memory (400 data), Auto-power save
Display Main and Sub displays: 5-digits LCD, max. 6000 digits
Display refresh rates 5 times/s (Capacitance measurement: 0.05 to 2 times/s, depending on measured value, Temperature: 1 time/s )
Power supply LR6 (AA) alkaline batteries ×4, Continuous use: 100 hours
Dimensions and mass 93 mm (3.66 in)W × 197 mm (7.76 in)H× 53 mm (2.09 in)D, 650 g (22.9 oz) (including test leads holder and batteries)
Accessories Test lead L9207-10 ×1, Instruction manual ×1, LR6 alkaline battery ×4

* Zero-suppression: For small inputs below the guarantee range, zero is effectively displayed

Key Features

• 60000 count, 5-digit display, high-resolution measurements

• ±0.025% DC V basic accuracy, wide 20 Hz to 100 kHz AC V frequency characteristics

• Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)

• Includes multiple measurement functions such as DC+ACV, temperature, capacitance, and frequency

• Terminal shutter mechanism (prevents erroneous test lead insertion)

• Measure up to 10A with direct input

• Dual display lets you check voltage and frequency simultaneously

• Magnetic strap (Optional)

• Rear kickstand

• Store probes at the back of the tester

• Identify excessively high input with a red screen backlight

• Robust design capable of withstanding a drop from a height of 1 m

• USB communications function supports PC measurements (optional)

• Broad -15 (5°F) to 55°C (131°F) operating temperature range

Application Notes