Hioki CT7040 Series AC Flexible Current Sensor

Hioki CT7040 Series AC Flexible Current Sensor

Hioki clamp sensors are best-in-class measuring devices incorporating Hioki’s expertise in current sensing technology.

The Hioki CT7040 Series compromise of 600A/6000A AC flexible current sensors in three different loop sizes that pair with the detachable Display Unit to measure large currents in crowded wiring and confined spaces.

CAT IV 600 V, CAT III 1000 V

Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)* It is waterproof to maintain measurement function, and measuring the live part in wet condition increases the risk of electric shock.

CT7046 CT7045 CT7044
Rated measurement current 6000 A AC
Internal Measurement range 600A AC/ 6000A AC (Range is controlled by main device)
Max. allowable input 10000 A continuous (at 6000 A range, 45 to 66 Hz, requires derating )
Bandwidth 10 Hz to 50 kHz (±3dB)
(When used in combination with CM7290 or CM7291: 10 Hz to 1 kHz)
Amplitude and phase accuracy ±1.5 % rdg. ±0.25 % f.s. (f.s. is internal range, 45 to 66 Hz) ±1 deg
Output rate 1 mV/A (600 A*), 0.1 mV/A (6000 A)
*Selectable only when used with CM7290, CM7291, PQ3100
Max. rated voltage to earth AC 600 V (CAT IV), AC 1000 V (CAT III)
Loop diameter φ 254 mm (10.00 in) or less φ 180 mm (7.09 in) or less φ 100 mm (3.94 in) or less
Dust and water resistance * IP54 (when connected to a supported instrument, Do not make measurements when wet.)
Output connectors HIOKI PL 14
Operating temperature range -25 °C to 65 °C (-13 °F to 149 °F)
Dimensions Flexible loop cable diameter: φ7.4 mm (0.29 in), Cable length: Between flexible loop and battery box: 2.3 m (7.55 ft), Output cable: 20 cm (0.66 ft), Battery box25 mm (0.98 in)W × 72 mm (2.83 in)H × 20 mm (0.79 in)D
Mass 186 g (6.6 oz) 174 g (6.1 oz) 160 g (5.6 oz)
Accessories Instruction manual ×1

Model No. (Order Code)

CT7046 6000 A, φ254 mm (10.00 in)
CT7045 6000 A, φ180 mm (7.09 in)
CT7044 6000 A, φ100 mm (3.94 in)

Note: CT7040 series cannot be used alone. Use with the Display Unit CM7290, CM7291 to connect with Data Loggers and Memory HiCorders. When used in combination with CM7290 or CM7291, the frequency band of current display and waveform output becomes narrow.

Category:

You may also like…

Key Features

  • Thinner cables are easier to use in confined spaces and with complicated wiring
  • Supports large current measurements up to 6000 A
  • Wide 10 Hz to 50 kHz band with excellent frequency characteristics
  • Choose from three conductor diameter sizes
  • Ideal for site inspections by using detachable Display Unit
  • Four output formats to output data to loggers or other devices (via Display Unit ) WAVE, RMS, PEAK, Hz

 

 

Application Notes