Hioki CT6865 AC/DC Current Sensor

Hioki CT6865 AC/DC Current Sensor

The Hioki CT6865 has been discontinued. See Hioki CT6876A AC/DC Current Sensor

Hioki pull-through AC/DC current sensors are best-in-class devices for use with power meters, Memory HiCorders and high performance oscilloscopes.

The CT6865 is a DC to 20kHz/1000A sensor, ideal for capturing current signals from switching power supplies, inverters, power conditioners, etc. CAT III 1000 V

Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

Rated current 1000 A AC/DC
Max. allowable input 1200 A AC/DC
(Continuous 1800 A peak, up to 100 Hz, up to 40 °C (104 °F), other requires derating characteristics)
Frequency characteristics Amplitude: DC to 20 kHz
Phase: DC to 1 kHz
Amplitude and Phase accuracy DC ±0.05 % rdg. ±0.01 % f.s.
16 Hz ≤ f ≤ 66 Hz ±0.05 % rdg. ±0.01 % f.s., Phase: ±0.2°
Amplitude is defined to 20 kHz, Phase is defined to 1 kHz
Output voltage rate 2 V /rated current value
(voltage output with the Sensor Unit, use with a device having a 1 MΩ input resistance or higher)
Max. rated voltage to earth 1000 V AC/DC (50/60 Hz, CAT III)
Core diameter φ 36 mm (1.42 in)
Operating temperature, humidity -30°C to +85°C (-22°F to 185°F)
80% rh or less (with no condensation)
Power supply ±11 V to ±15 V DC (Power suppled via the Sensor Unit, which supports 100 to 240 V AC)
Power consumption 7 VA max.
(at 1000 A/55 Hz, ±12 V power requirement)
Dimensions and mass 160 mm (6.30 in)W × 112 mm (4.41 in)H × 50 mm (1.97 in)D, 980 g (34.6 oz), cord length 3 m (9.84 ft)
Accessories Instruction manual ×1, Mark bands ×6

Compatible models…CT6865 (-05)

Compatible models CT6865 CT6865-05
Power Analyzer PW6001, PW3390 △ (Requires CT9900)
CT ratio 2
OK
Power Analyzer 3390 OK CT ratio 2 △ (Requires CT9901)
CT ratio 2
Power HiTester 3193 series OK CT ratio 2 △ (Requires CT9901)
CT ratio 2
Current Unit 8971 △ (Requires the 9318)
CT ratio 2
△ (Requires the 9318, CT9901) CT ratio 2
F/V Unit 8940 △ (Requires the 9318, 9705) CT ratio 2 △ (Requires the 9318, 9705, CT9901) CT ratio 2

Category:

You may also like…

Key Features

  • 1000A large current measuring applications in the fields of electric and hybrid electric vehicles
  • Operating temperature range of -30°C to 85°C
  • Super high precision, ±0.05% amplitude accuracy, ±0.2° phase accuracy
  • DC to 20 kHz bandwidths with excellent frequency characteristics
  • Ideal for evaluation of solar power generation and fuel cells to measure battery charge and discharge and the secondary side of inverters
  • For observing waveforms to be used with the oscilloscopes or Memory HiCorders (use with SENSOR UNIT)

 

Application Notes