Hioki CT6843A AC/DC Current Clamp
Hioki’s clamp type AC/DC current sensors can be connected directly to Hioki Power Analyzers and Memory HiCorders.
Also, it can be connected to Power Meters, Oscilloscopes, DMMs, etc. by using an optional sensor unit.
Use with an instrument with a high input impedance of 1 MΩ or higher.
Replacing the discontinued Hioki CT6861 200 A AC/DC, PL23 terminal and Hioki CT6861-05 200 A AC/DC, ME15W terminal
Basic specifications
Rated current | 200 A AC/DC |
---|---|
Frequency bandwidth | Amplitude: DC to 700 kHz |
Core diameter | φ 20 mm |
Max. allowable input | ±600 A peak (Within 20 ms in an environment of 40°C or less) |
Output voltage | 10 mV/A |
Output resistance | 50 Ω ± 10 Ω/td> |
Amplitude accuracy | DC: 0.2% + 0.02%, DC < f ≤ 100 Hz: 0.2% + 0.01% |
Power consumption | 6 VA max. (at 200 A/55 Hz, ±12 V power requirement) |
Linearity | ±20 ppm Typical |
Common-Mode Voltage Rejection Ratio (CMRR) | DC to 1 kHz:150 dB or greater
1 kHz to 10kHz:135 dB or greater 10 kHz to 100 kHz:115 dB or greater 100 kHz to 500 kHz:95 dB or greater (effect on output voltage and common mode voltage) |
Automatic phase correction | Automatically performs phase correction when connected to PW8001 |
Operating temperature, humidity | -40 °C to +85 °C, 80% RH or less |
Withstand voltage | AC 4260 V |
Standards | Safety: IEC 61010 Type D, EMC: IEC 61326 |
Power supply | Power suppled via the Power Analyzer PW8001, PW6001, PW3390, Sensor Unit CT9555, CT9556, CT9557, or 3CH CURRENT UNIT U8977 |
Dimensions and mass | 153mm W × 67mm H × 25mm D, 370g, cord length: 3 m |
Accessories | Instruction manual ×1, Mark bands ×6, Carrying Case ×1 |