CT6841A AC/DC Current Probe
Hioki’s clamp type AC/DC current sensors can be connected directly to Hioki Power Analyzers and Memory HiCorders. Also, it can be connected to Power Meters, Oscilloscopes, DMMs, etc. by using an optional sensor unit.
Use with an instrument with a high input impedance of 1 MΩ or higher.
The Hioki CT6841A AC/DC Current Probe replaces the discontinued CT6841 20 A AC/DC, PL23 terminal and CT6841-05 20 A AC/DC, ME15W terminal
Basic specifications
Rated current | 20 A AC/DC |
---|---|
Frequency bandwidth | DC to 2 MHz |
Core diameter | φ 20 mm |
Maximum input | ±60 A peak (Within 20 ms in an environment of 40°C or less) |
Output voltage | 100mV /A |
Output resistance | 50 Ω ± 10 Ω |
Amplitude accuracy | DC: 0.2% + 0.05%, DC < f ≤ 100 Hz: 0.2% + 0.01% |
Linearity | ±20 ppm Typical |
Common-Mode Voltage Rejection Ratio (CMRR | DC to 1 kHz:140 dB or greater 1 kHz to 10 kHz:125 dB or greater 10 kHz to 100 kHz:100 dB or greater 100 kHz to 1 MHz:80 dB or greater (effect on output voltage and common mode voltage) |
Automatic phase correction | Automatically performs phase correction when connected to PW8001 |
Operating temperature, humidity | -40 °C to +85 °C, 80% RH or less |
Withstand voltage | AC 4260 V |
Power supply | Power suppled via the Power Analyzer PW8001, PW6001, PW3390, Sensor Unit CT9555, CT9556, CT9557, or 3CH CURRENT UNIT U8977 |
Max. rated power | 5 VA or less (When measuring 20 A/55 Hz with ±12 V power supply) |
Dimensions and mass | 153mm W × 67mm H × 25mm D, 370g, cord length: 3 m |
Accessories | Instruction manual ×1, Mark bands ×6, Carrying Case ×1 |