VW 80000 / LV 124 : Battery test systems, Low Voltage

VW 80000 / LV 124 : Battery test systems, Low Voltage

The BOLAB 100-35R-TS series presents a globally unique solution for the simulation of 12V / 24V / 48V systems acc. LV124 / VW80000 and numerous other standards. All curves relevant for this standard are stored in the integrated curve library.

The Bolab 100-35R-TS series are linear precision 4-quadrant power amplifiers for fast voltage and current signals – each positive and negative (bipolar). They also work as sink in applications to absorb power. Extremely high bandwidth at highest power requirements, necessary for fast signals, characterizes this series. We also want to distinguish the modular design that allows to build up systems with up to 18 kW.

The BOLAB arbitrary power amplifiers include a huge memory of 1,000,000 data points to store arbitrary waveforms in the instrument itself. No arbitrary waveform generator or any other controlling instrument is needed. This makes these 4-quadrant amplifiers unique in the world market. The easy to use WaveMaster software, that is standard in scope of delivery, allows to generate waveforms in a graphical user interface or via tabular input. This test equipment is perfectly suited for tests acc. automotive standards LV124 / VW80000.

Voltage- and current control

Both voltage and current control of the mighty amplifiers is possible. This can be selected on the front panel of the instrument. Control input is 0 … ±10 V for 0 … ±Vrated respectively 0 … ±Irated.

Selectable operating voltage

Three selectable operating voltage ranges allow to adapt to applications for high voltage / low current or low voltage / high current. Especially when controlling extremely low impedance loads, the operating voltage range can be reduced to one third of the maximum output voltage. This leads to an immense reduction of power dissipation.

Amplifier control from PC

In standard, a USB interface is included to communicate and control the instruments by PC. Optionally a LAN interface can be added.

Protective functions

Various protective functions avoid damage of the instrument and also guarantee protection for tested devices. Output voltage and current can be limited and also over temperature shutdown is included.
The inside calculation of power dissipation and totally monitoring of current ensure perfect short circuit and over voltage protection.
Also for security aspects an interlock shut down can be triggered.

Monitor outputs

Located on the back of the instruments there are monitor outputs for voltage and current with its measured values. Output values are 0 … ±10 for 0 … ±Vrated respectively 0 … ±Irated.

Ouput ON/OFF

With its output on/off switch on the front of the instruments, the output can be activated or deactivated. When deactivating, there is a completely galvanic interruption to the tested devices.

 

35V Models, Voltage Range +35V to -30V

 

Models Current Output power Dimensions
105-35R-TS 20 A 400 W 3 U
110-35R-TS 40 A 1 kW  4 U
120-35R-TS 76 A 2 kW  14 U
130-35R-TS 114 A 3 kW 18 U
140-35R-TS 152 A 4 kW 22 U
150-35R-TS 190 A 5 kW 26 U
160-35R-TS 228 A 6 kW 30 U
180-35R-TS 304 A 8 kW 2 X 22 U
200-35R-TS 380 A 10 kW 2 X 26 U
220-35R-TS 456 A 12 kW 2 X 30 U
250-35R-TS 570 A 15 kW 3 X 26 U
280-35R-TS 684 A 18 kW 3 X 30 U

 

70V Models, Voltage Range +70V to -30V

 

Models Current Output power Dimensions
105-70R-TS 15 A 500 W 3 U
110-70R-TS 40 A 1 kW  4 U
120-70R-TS 76 A 2 kW  14 U
130-70R-TS 114 A 3 kW 18 U
140-70R-TS 152 A 4 kW 22 U
150-70R-TS 190 A 5 kW 26 U
160-70R-TS 228 A 6 kW 30 U
180-70R-TS 304 A 8 kW 2 X 22 U
200-70R-TS 380 A 10 kW 2 X 26 U
220-70R-TS 456 A 12 kW 2 X 30 U
250-70R-TS 570 A 15 kW 3 X 26 U
280-70R-TS 684 A 18 kW 3 X 30 U

 

75V Models, Voltage Range +75V to -75V

 

Models Current Output power Dimensions
105-75R-TS 11 A 500 W 3 U
110-75R-TS 40 A 1 kW  4 U
120-75R-TS 76 A 2 kW  14 U
130-75R-TS 114 A 3 kW 18 U
140-75R-TS 152 A 4 kW 22 U
150-75R-TS 190 A 5 kW 26 U
160-75R-TS 228 A 6 kW 30 U
180-75R-TS 304 A 8 kW 2 X 22 U
200-75R-TS 380 A 10 kW 2 X 26 U
220-75R-TS 456 A 12 kW 2 X 30 U
250-75R-TS 570 A 15 kW 3 X 26 U
280-75R-TS 684 A 18 kW 3 X 30 U

Category:

Key Features

  • DC – 200 kHz bandwidth
  • DC – 1 MHz (small signal -3 dB)
  • Output voltage -30V /+35 Vpk
  • Rise / fall time 100 V/µs
  • Arbitrary function with 1,000,000 memory points
  • Generation of waveforms with synchronous data acquisition
  • Modular Expandable
  • Individual Waveform Generation and Standard Libraries included
  • Unlimited Waveform size
  • 2 different Waveforms synchronously
  • DLL’s for LabView, Vector CANoe / CAPL, C#, C++, ANSI C, Python, etc.
  • Simulation of imported oscilloscope waveform/li>
Standards
LV 124
LV 148
VDA 320
BMW GS 95024
BMW GS 95026
Mercedes MBN LV 124-1
Mercedes MBN LV 148
Volkswagen VW 80000
JLR
PSA
GMW
ISO 16750-2
ISO 21780
ISO 7637
etc.

Application Notes