4761 / 4764 High Precision Current Comparator

4761 / 4764 High Precision Current Comparator

The high precision Current Comparators (current transformers) are used to convert high currents to a lower, measurable level. The errors of conventional standard current transformers inevitably depend on their burden. A magnetic flux in the core produces the e.m.f. which sustains the secondary current in the burden. This disadvantage has been eliminated by the
development of the new current comparators. An indicator winding measures the magnetic flux in the core, while an amplifier – by regulating the current in a compensating winding – ensures that the amplitude of the residual flux in the core is approximately zero.

Model 4761 4764
Primary current, Upper terminals 200A 500A
Primary current, lateral window connection: 1000A 5000A

Advantages

  • Wide current measurement spectrum – Extended current measurement, from mA to kA allowed with one single device. The secondary tapping is provided for maximum versatility.
  • Accuracy at best level – The 476x units are prepared for accuracy testing of current instrument transformers with most stringent accuracy requirements – 476x units are qualified for use as standard current transformers in metrology institutes
  • Extending other instruments measurement capabilities – 476x units allows a current measurement range extension above 15 A for the 2823 series.
  • On-board fault indication and unit self-protection
  • Ease of handling and mobility – Standard units customized for temporary and mobile test arrangements.
  • Highest versatility in current taps combinations

Applications

  • Current instrument transformers (LV/MV/HV)
  • Current instrument transformers for switchgears, MV/HV cables, busbars, bushings
  • Losses on shunt reactors
  • Power capacitors
  • Metrology institutes
  • Research and development

Category:

Key Features

  • Wide measuring range with up to 155 primary current taps (5 … 5000 A) on type 4764, 2 secondary current taps (5 A/1 A), up to 200 % of the nominal current at full accuracy
  • Outstanding accuracy and stability over a very broad working range (1 … 200 % IN)
  • Suitable for shunt reactor losses measurement together with the 2823-REF
  • Suitable for power capacitors C/tan d measurement on high capacitance values
  • Built-in overload protection with indication, overtemperature indication on type 4764
  • 4761 fitted with handles. 4764 fitted with handles and castors
  • Reversible unit : secondary/primary

Application Notes