Raditeq RadiPower® Power Meter| 10 MHz – 8GHz low frequency extension

Raditeq RadiPower® Power Meter| 10 MHz – 8GHz low frequency extension

RadiPower® – 3008W – 8 GHz Fast Synchronous Power Measurements · Flexible

Specifications

  • Measuring function: RMS power, peak max hold and Burst mode
  • Measurement speed: (1) 10, 50, 100 kS/s, 1, 5, 10, 20, 33 MS/s
  • Storage capacity: 100.000 samples 100.000 bursts
  • Resolution: 0,01 dBMeasuring units dBm or Watt
  • Zero adjustment: Not required
  • Input damage level: >+20 dBm

For further technical specifications, please refer to datasheet

 

Standard delivered including

  • RadiPower 3006W RF Power Meter
  • USB Cable
  • A protective Case of the RadiPower
  • Digital Manuals on a USB drive
  • Hard Copy Quick Start Guide

Category:

Key Features

Extremely Fast
In order to achieve this measurement requirements of the ETSI standards the sampling speed of the RadiPower® power sensor has been increased to maximum 5 MS/s. The RPR3006W and RPR3008W is also equiped with a hardware trigger input/output that allows synchronous power measurements of wideband data transmission devices with multiple inputs/outputs (MIMO).

Accurate
Next to speed, accuracy is another main requirement when performing RF power measurements of wireless devices.
The RPR3006W and RPR3008W allows high precision RF power measurements with a high dynamic range of 60 dB. The power meter provides a accuracy of ± 0,2 dB and is well within the requirements for measurements in accordance to ETSI standards.

Easy to use
The RadiPower® Wireless is equipped with an USB interface which enables direct connection of the Power sensors to a PC USB port. Together with the RadiPower USB power sensor a RadiMation® FREE freeware package is delivered to enable direct control of the power meter settings and display the measurement results on the PC screen. The RadiMation® Freeware also enables synchronous triggering of multiple RadiPower® Wireless power sensors.

‘Burst’ mode
The RadiMation® Freeware includes a ‘Burst’ mode with user selectable measurement speed/time to capture the
wideband Burst/Pulse signals and calculate the measurement parameters, maximum RMS power, duty cycle, medium utilization and maximum sequence time. This mode is fully compliant with the measurement methods as defined in the ETSI standards for wideband data transmission systems EN 300 328 (2,4 GHz) and EN 301 893 (5 GHz). In burst mode, the RadiPower can store the information of 100.000 bursts and observation time up to 60 seconds. For each burst the average power and timing data is stored in the buffer. The RadiPower® uses a sample speed of 1 or 5 MSps in combination with a RMS detector to ensure correct measurements on wideband modulating transceivers.

Synchronized measurements
For MIMO devices with for example six antenna ports, an equal amount of RPR3006W power heads can be daisychained using the MMCX connectors enabling synchronised triggering of all six RadiPower meters. RadiMation Freeware captures the samples of each power meter simultaneously and calculates the total combined power according to the ETSI 300 328 standard.

Software support
The standard delivered RadiMation® Freeware supports all RadiPower® measurement modes. Using the instrument command codes the RadiPower® Wireless can be used with any other software control package.

Application Notes