Instruments /
Partial Discharge
A Partial Discharge Tester (PDT) is an essential tool used in the electrical power industry to measure partial discharges in high-voltage equipment. Partial discharges are tiny electrical sparks that can occur within the insulation of high-voltage equipment. They can lead to the degradation of the insulation and eventually cause equipment failure. By using a PDT, engineers can detect and monitor partial discharges, helping to prevent equipment failure and ensure the reliability of the power grid.
A typical PDT consists of a high-voltage source, a coupling capacitor, a measuring device, and a computerized data acquisition system. The high-voltage source applies a high voltage to the equipment under test, and the coupling capacitor allows for the measurement of partial discharges. The measuring device detects and measures the magnitude and frequency of the partial discharges, which can be used to assess the health of the equipment. The data acquisition system collects and analyzes the data, providing engineers with detailed information on the condition of the equipment.
PDTs are used in a wide range of applications, including testing of power transformers, cables, switchgear, and other high-voltage equipment. They are especially useful for identifying potential problems in aging equipment or equipment that has undergone repairs or modifications.
A Partial Discharge Tester (PDT) is an essential tool used in the electrical power industry to measure partial discharges in high-voltage equipment. Partial discharges are tiny electrical sparks that can…
...occur within the insulation of high-voltage equipment. They can lead to the degradation of the insulation and eventually cause equipment failure. By using a PDT, engineers can detect and monitor partial discharges, helping to prevent equipment failure and ensure the reliability of the power grid.
A typical PDT consists of a high-voltage source, a coupling capacitor, a measuring device, and a computerized data acquisition system. The high-voltage source applies a high voltage to the equipment under test, and the coupling capacitor allows for the measurement of partial discharges. The measuring device detects and measures the magnitude and frequency of the partial discharges, which can be used to assess the health of the equipment. The data acquisition system collects and analyzes the data, providing engineers with detailed information on the condition of the equipment.
PDTs are used in a wide range of applications, including testing of power transformers, cables, switchgear, and other high-voltage equipment. They are especially useful for identifying potential problems in aging equipment or equipment that has undergone repairs or modifications.
-
The 5289 provides a motorized tuneable 15 kV, 100 kVA inductor coil to be used together with the MIDAS 2881 system and increase its test object...FIND OUT MORE
-
The capacitors are of sturdy and rugged and are for indoor operation. Insulation is reinforced epoxy fiberglass tube filled with oil. Decouples...FIND OUT MORE
-
The coupling capacitor type 9230/25/1-PD includes a high voltage capacitor, a high voltage filter and a measuring impedance (modified AKV 9310) in a...FIND OUT MORE
-
The coupling capacitor type 9230/30/9-PD includes a high voltage capacitor, a high voltage filter and a measuring impedance in a compact design. It...FIND OUT MORE
-
The capacitors are of sturdy and rugged and are for indoor operation. Insulation is reinforced epoxy fiberglass tube filled with oil. Decouples...FIND OUT MORE
-
The divider is sturdy and rugged and for indoor operation. The insulator is a reinforced epoxy fiberglass tube filled with oil. It consists of a...FIND OUT MORE
-
The AKV 9310 series of quadripole (measuring impedance) is a fully passive measurement system optimized for use with the DDX 9121b series of partial...FIND OUT MORE
-
The AKV 9330 has been specially designed for Partial Discharge (PD) testing of power capacitors. It addresses two major problems associated with...FIND OUT MORE
-
The AKV 9360 is a measuring impedance (sometimes also called coupling device or quadripole). It is a fully passive and optimized for use with the DDX...FIND OUT MORE
-
The AQS 9110a series of quadripole (measuring impedance) is a fully passive measurement system optimized for use with the DDX series of partial...FIND OUT MORE
-
Since The first PD detector in the 60’s, Haefely-Tettex combined the best of both worlds in the release of the DDXTM 9121b Partial Discharge...FIND OUT MORE
-
Since the first PD detector in the 60’s, Haefely-Tettex combined the best of both worlds in the release of the DDXTM 9121b Partial Discharge...FIND OUT MORE
-
The KAL 9510 has been designed to fulfil the standard requirements of a PD calibrator. Its very wide range (from 1 pC to 50 nC), its small injection...FIND OUT MORE
-
Partial discharge calibrator KAL 9511 is a successor to the popular Tettex 9216. KAL 9511 covers a wide range of applications. It is compact, easy to...FIND OUT MORE
-
The KAL 9520 has been designed to exceed the standard requirements of a PD calibrator. Its wide range (from 100 fC to 50 nC), its small injection...FIND OUT MORE
-
Radio Influence Voltage (RIV) calibrator KAL 9531 is a successor to the popular Tettex 9220a. However, KAL 9531 exceed functions of its predecessor...FIND OUT MORE