3695 Programmable Electronic Voltage Burden

3695 Programmable Electronic Voltage Burden

The programmable electronic voltage burden, type 3695 is designed for efficient testing of voltage instrument transformers. It replaces traditional burdens which are built with passive resistances and inductances.
The wide range of programmable impedances enables the emulation of most existing national and international standard burdens as well as customer-specific values.
The electronic voltage burden constantly monitors the applied burden accuracy and indicates any burden parameter deviation that may occur when testing an instrument transformer for accuracy, thereby connection and handling errors in the complete accuracy test sytem are minimized.
The instrument is protected against user setting errors, overvoltages, overcurrents and overheating. The error messages are indicated on the dot matrix display installed on the front panel of the device.
In conjunction with the type 2767 automatic instrument transformer test set and the type 4860 electronic voltage divider, the system makes it possible to integrate burdens into a computer-controlled test system.
For applications requiring apparent powers higher than 75 VA, the remotely controlled additional external passive voltage burden type 3697 expands the power range of the programmable electronic voltage burden type 3695 to 400 VA.

    Advantages

  • High versatility – 3695 is a universal and standardized voltage burden offering a wide burden spectrum. The built-in test frequency detection and auto-selection eliminates the disadvantage of having one instrument per power frequency value
  • Accuracy at best level – 3695 + 3697 units are prepared for accuracy testing of voltage instrument transformers with most stringent accuracy requirement – These units are qualified for use in metrology institutes
  • Configuration flexibility – Unit replacement is not necessary when power expansion is required, a quick and easy unit extension is available with type 3697
  • Optimized investment – Many classical passive burdens can be replaced by a single electronic voltage burden type 3695
  • Compatibility – Unit can be integrated with a variety of instrument transformer test sets, such as Tettex types 2767 or other makes
  • Upgradeable to an automatic test system – By combination with a device type 2767 or 2769
  • Optimized setting time – Unit can be quickly and easily configured for a new test using pre-defined burden values from applicable standards or user defined set of values
    Applications

  • Voltage instrument transformers (LV/MV/HV)
  • On-site testing of high voltage instrument transformers
  • Metrology institutes
  • Research and development

Category:

Key Features

  • The voltage burden type 3695 is suitable for standard voltage ratings. Power levels are selectable over a wide range (up to 75 VA) with cos B = 0.1 to 1 at 50 and 60 Hz
  • High accuracy of 1% – even with additional external passive burden type 3697 connected
  • The power range can be expanded to 400 VA with an additional passive voltage burden type 3697
  • The load generation principle used in the 3695 unit is electronic, not based on classical passive burdens
  • The internal resistance of the measuring system can be parametrised from the unit user interface and is automatically compensated
  • Remote control possibility via IEEE 488 or RS 232C interfaces
  • Burden values can be retrieved from stored tables based on IEC 61869-3, ANSI C57.13 and VDE 0414 Part 2
  • Nine individual burden settings (SN, cos B) can be stored and retrieved as needed