Hioki 3283 CLAMP ON LEAK HiTESTER

Hioki 3283 CLAMP ON LEAK HiTESTER

The Hioki 3283 Clamp On Leak HiTester has been discontinued. Please See Hioki CM4003 AC Leakage Clamp Meter

Hioki clamp meters are best-in-class measuring devices incorporating Hioki’s expertise in current sensing technology. The Hioki 3283 series are leakage current handheld clamp meters with a 10mA to 200A range and 10 μA resolution. Model 3283 has output capabilities for advanced monitoring on recording equipment, and Model 3283-20 complies with EN 61010-2-032:2012 Type A standards to measure uninsulated hazardous live conductors such as busbars.

Basic specifications (Accuracy guaranteed for 3 years, Post-adjustment accuracy guaranteed for 3 years)

3283 3283-20
AC Current range 10.00 m/ 100.0 m/ 1.000/ 10.00/ 200.0 A, 5 ranges, (40 Hz to 2 kHz, True RMS), Basic accuracy: ±1.0 % rdg. ±5 dgt., Guaranteed accuracy: from 1.00 mA
AC Voltage range N/A
Frequency range 30.0 Hz to 1000 Hz, 2 ranges, Basic accuracy: ±0.3 % rdg. ±1 dgt.
Crest factor 2.5 or less (1.5 at 200 A range)
Filter function Cut off frequency at filter ON: 180 Hz (-3dB)
Output REC output for current: DC 1 V/f.s. (2 V/f.s. at only 200 A range), response time: less than 200 ms.
MON output for current: AC 1 V/f.s. (2 V/f.s. at only 200 A range), 5 Hz to 15 kHz frequency bandwidth (-3 dB)
N/A
Other functions Max./ Min./ Average value record, Data hold, Auto power off
Display LCD, max. 2000 dgt., Display refresh rate: 4 times/s (Fast), 1 time/3s (Slow), 4 times/s (bar graph)
Power supply 6LR61 (Stacked alkaline battery) ×1, or 6F22 (Stacked manganese battery), Continuous use: 40 hours (using 6F22),
AC adapter 9445-02/-03
6LR61 (Stacked alkaline battery) ×1, or 6F22 (Stacked manganese battery), Continuous use: 40 hours (using 6F22)
Core jaw dia. φ 40 mm (1.57 in)
Dimensions and mass 62 mm (2.44 in) W × 225 mm (8.86 in) H × 39 mm (1.54 in) D,
400 g (14.1 oz)
Accessories Carrying case 9399 ×1, Hand strap ×1, Stacked manganese battery (6F22) ×1, Instruction manual ×1 Carrying case 9399 ×1, Hand strap ×1, Alkaline battery (6LR61) ×1, Instruction manual ×1

Category:

Key Features

• Measure leak current using highly sensitive 10μA resolution (at 10.00 mA range)

• Indicate 50/60 Hz leak current components with the filtering function

• Monitor leak current conditions in combination with a Memory HiCorder (monitor output, Model 3283 only)

• 3283-20: EN 61010-2-032:2012 Type A to measure uninsulated hazardous live conductors such as busbars

Application Notes