Hioki CT6710 CURRENT PROBE

Hioki CT6710 CURRENT PROBE

Hioki flat bandwidth current probes are best-in-class current sensors for use with Memory HiCorders and high performance oscilloscopes. The Hioki CT6710 is a 3-range, high-sensitivity current probe that offers a wide DC to 50 MHz bandwidth and 200 μA to 30 A input, letting your capture signals across an expansive current range, from steady state to transient currents, when developing switching power supplies, inverters, and motor controllers.

Basic specifications (Accuracy guaranteed for 3 years, Post-adjustment accuracy guaranteed for 3 years)

Frequency bandwidth DC to 50 MHz (-3 dB)
Rise time 7.0 ns or shorter
Delay time (Typical) 30 A range: 12 ns, 5 A range: 12 ns, 0.5 A range: 13 ns
(Delay time relative to rising waveform of input signal 1 ns)
Noise level 75 μA rms max (at 0.5 A range, using 20 MHz band measuring instrument)
Max. rated current 30 A range: 30 A rms, 5 A range: 5 A rms, 0.5 A range: 0.5 A rms
(DC, and sine wave, requires derating at frequency)
Max. allowable peak current 30 A range: ±50 A peak (within the input limit time 2 s)
5 A range: ± 7.5 A peak,
0.5 A range: ± 0.75 A peak (< 10 MHz), ±0.3 A peak (≥ 10 MHz)
Amplitude accuracy 30 A range: ±3.0% rdg. ±1 mV, (Typical) ±1.0% rdg. ±1 mV (≤ 10 Arms, DC, 45 to 66 Hz sine wave, within the maximum peak current of each range)
5 A range: ±3.0% rdg. ±1 mV, (Typical) ±1.0% rdg. ±1 mV (DC, 45 to 66 Hz sine wave, within the maximum peak current of each range)
0.5 A range: ±3.0% rdg. ±10 mV, (Typical) ±1.0% rdg. ±10 mV (DC, 45 to 66 Hz sine wave, within the maximum peak current of each range)
Output rate 30 A range: 0.1 V/A, 5 A range: 1 V/A, 0.5 A range: 10 V/A, (The output of this probe is internally terminated, so connect to voltage input equipment with high input impedance such as 1MΩ)
Measurable conductors φ 5 mm (0.20 in), Insulated conductor
Power supply Supplied from Power Supply 3269, Probe Power Unit Z5021
Cable length Sensor cable (between relay box and sensor): 1.5 m (4.92 ft)
Power cable: 1.0 m (3.28 ft) (Power plug: FFA.0S.304.CLAC37Y / LEMO inc.)
Dimensions and mass Sensor: 155 mm (6.10 in)W × 18 mm (0.71 in)H × 26 mm (1.02 in)D, Relay box section: 45 mm (1.77 in)W × 120 mm (4.72 in)H × 25 mm (0.98 in)D
Terminator section: 29 mm (1.14 in)W × 83 mm (3.27 in)H × 40 mm (1.57 in)D mm, 370 g (13.1 oz)
Accessories Instruction manual ×1, Carrying case ×1

Category:

Key Features

• 3 ranges in a single probe – 30 A, 5 A, 0.5 A.  Observe a wide current range from micro currents to 30 A.

• Wide band: DC to 50 MHz (-3 dB)

• High S/N ratio and 10 times output rate: Observe waveforms at 100 μA/div at oscilloscope maximum voltage sensitivity setting of 1 mV/div

• Directly connect to an oscilloscope’s BNC input terminal *1

• Also available: CT6711 Current Probe with DC to 120 MHz bandwidth

Application Notes